Armering med geonät vid förstärkning av väg Prov vid Backe 1990 = Reinforcement with geogrid inn road strengthening : experiment at Backe 1990 : construction report.

Author(s)
Lindh, E.
Year
Abstract

This construction report describes an experiment in which geogrids were used to strengthen an existing road. The experiment was carried out during summer 1990 in the county of Jaemtland, northern Sweden. The aim of the experiment was to determine whether reinforcement of a road pavement can reduce the amount of pavement material required and thereby help to reduce the exploitation of natural resources in the form of gravel and rock when strengthening roads with poor bearing capacity. On the test sections, the added thickness of the pavement to be strengthened was reduced from 550 mm to about 250 mm. The reinforcement was laid on the existing road surface, but with a thin layer (about 30 mm) of sand beneath the grid (about 30 mm) of sand beneath the grid for most of the distance along the road. This was done to facilitate penetration (keying) of the gravel from the roadbase, which here consists of crushed rock, 0-35 mm. The surface of the roadbase was levelled with a thin (about 20 mm) layer of crushed rock 0-18 mm. A wearing course of Y1G (single surface treatment) was applied. (A)

Request publication

2 + 6 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
C 6359 S /22 /35 /52 / IRRD 847095
Source

Linköping, Swedish Road and Traffic Research Institute VTI, 1991, II + 23 + 29 p., 2 ref.; VTI Meddelande ; No. 650 - ISSN 0347-6049

Our collection

This publication is one of our other publications, and part of our extensive collection of road safety literature, that also includes the SWOV publications.