Biofidelity evaluation of the THOR advanced frontal crash test dummy.

Author(s)
Shaw, G. Crandall, J.R. & Butcher, J.
Year
Abstract

Ten 48 km/h frontal sled tests were conducted to evaluate the biofidelity of the THOR dummy. Three replicate tests were conducted with THOR, three with a 50th percentile male Hybrid III dummy, and four with Post Mortem Human Surrogates (PMHS). The tests, conducted in a buck representing a mid-size US sedan, included a force-limited three-point belt system with buckle-side pretensioner and a driver side air bag. Following the tests, selected parameters were used to compare THOR's responses with those of the Hybrid III dummy and the PMHS. The results were mass scaled in order to account for size differences between the subjects. Based on cadaveric response corridors, the sled test results provided evidence that THOR is more biofidelic than the Hybrid III dummy. THOR lap belt loads, upper spine (T1) movement, head acceleration, and movement of the anterior chest wall were more similar to those of the PMHS than were those of the Hybrid III. However, THOR recorded less head forward movement and pelvic acceleration than did the PMHS. (A)

Request publication

9 + 11 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
C 19069 (In: C 19067) /84 / ITRD E206424
Source

In: Proceedings of the 2000 International IRCOBI Conference on the Biomechanics of Impacts, Montpellier, France, September 20-22, 2000, p. 11-29, 19 ref.