We11s,A.E.
Abstract

Tests utilizing an equilibrator and an aqueous alcoholsolution (3.41 mg/mL) indicate that higher than exgectedresults will be obtained on a Borkenstein Breathalizer ifthe ambient temperature is higher than the solution tem-peratzxm and lover results Will be obtained if the ambienttemperature is lover than the solution temperature. IMaxi-mum differences veere -16 mg/100 mL When ambient tempera-ture was 9.9C Warmer than the solution.