There is a need for a simple and inexpensive anode for use in the impressed-current cathodic protection (cp) of inland concrete piers that are deteriorating because of salt-induced corrosion of rebars. in search of such an anode, a new water-based conductive coating was used recently on the cathodic protection of some concrete piers in virginia. further, as a possible means of eliminating the need forregular site visits to inspect and ensure that the cp is functioning properly (a disadvantage common to existing cp systems), a microprocessor-based data acquisition device that facilitates remote monitoring was tested with the system. the design, the installation, and the performance of the cp system during its first year of operation are described. this paper appears in transportation research record no. 1304, highway maintenance operations and research 1991.

Request publication

6 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
I 850353 IRRD 9210
Source

TRANSPORTATION RESEARCH RECORD WASHINGTON D.C. USA 0361-1981 SERIAL 1991-01-01 1304 PAG: 160-166 T6

Our collection

This publication is one of our other publications, and part of our extensive collection of road safety literature, that also includes the SWOV publications.