Abstract
In this paper human volunteer head/neck dynamic response is compared with that of a Hybrid III head and neck. A detailed analysis of 15 g -X vector exposures is presented. Math model simulations using a linkage model to simulate the response of the beam-like Hybrid III neck to-X sled acceleration profiles are presented, as well as simulations of human runs using a similar linkage model.