Abstract
An electrical model for the description of the terminal voltage behaviour of lead accumulators is presented. The measurement on the battery block of an electric vehicle or some model makes it certain that not the data of one lonely, possible wrong, cell are obtained. The simulation of the battery shows in cycle working as well as in constant current discharge a good correspondence with the results of the measurements.