Evaluation of the BioRID P3 and the Hybrid III in pendulum impacts to the back: a comparison with human subject test data.

Author(s)
Linder, A. Svensson, M. & Viano, D.
Year
Abstract

Crash test dummies able to mimic the motion of a human are needed to assess the protective performance of seats and the Hybrid III dummy by means of a recently available set of human subject data. The study also meets the need for validation of the BioRID P3 at a higher impact severity than that previously achieved. The BioRID P3 and the Hybrid III were evaluated by means of pendulum impacts to the back and compared with data from previously run cadaver tests. Seated dummies were struck with a pendulum with a mass of23 kg and an impact velocity of 4.6 m/s at the level of the 6th thoracic vertebra. The results showed that peak values and temporal responses of the BioRJD P3 was closer to that of the corridor of the cadavers than the Hybrid III in terms of horizontal, vertical, and angular displacement of the head and of the head relative to T1. (Author/publisher).

Request publication

16 + 2 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
I E115514 /84 / ITRD E115514
Source

Traffic Injury Prevention. 2002 /06. 3(2) Pp159-66 (24 Refs.)

Our collection

This publication is one of our other publications, and part of our extensive collection of road safety literature, that also includes the SWOV publications.