High chest accelerations in the Hybrid III dummy due to interference in the hip joint.

Author(s)
Abramoski, E. Warmann, K. Feustel, J. Nilkar, S. & Nagrant, N.J.
Year
Abstract

The design of the Hybrid III dummy's hip joint limits the allowable relative rotation between dummy's lower torso and femur assembly. This limited motion is thought to cause abnormally high chest accelerations in some front barrier crash tests. This paper describes static testing and computer modeling to quantify the hip joint range of motion and its effect on dummy chest accelerations. A series of HYGE sled tests were completed using modified hip joints in order to verify model results. (A)

Request publication

16 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
C 4531 (In: C 4511 [electronic version only]) /84 / IRRD 879209
Source

In: Proceedings of the 38th Stapp Car Crash conference, Fort Lauderdale, Florida, October 31 - November 4, 1994, p. 281-291, 2 ref.