Long-term strains in a support cantilever of the Cheswick-Boston Manor Viaduct M 4.

Author(s)
Tyler, R.G.
Year
Abstract

Acoustic strain gauges and thermocouples were placed in a reinforced concrete cantilever during 1964 with a view to providing information on the creep and shrinkage of a normal reinforced concrete constitution. Results are discussed.

Publication

Library number
B 3837 [electronic version only] /24/32/ IRRD 206629
Source

Crowthorne, Transport and Road Research Laboratory TRRL, 1973, 18 p., 7 fig., 5 tab., 10 ref.; TRRL Report LR- 564