Road lighting : assessment of an installation based on the contrast of a standard target.

Author(s)
Menard, J. & Cariou, J.
Year
Abstract

The paper reports experimental work to check the validity and significance of Keck's proposed criteria for the assessment of road lighting installations. The experimental site was in Rouen, lit on one side by five semi-cutoff lanterns whose height and spacing can be varied. 21 observers estimated the visibility level of a target (20 cm x 20 cm) for various positions and spacing/height ratios of the luminaires. The averages of the responses on a scale 1 to 4 are compared with visibility levels calculated with either experimental or theoretical luminance values. In both cases the optimum correlation (r=0.94) was obtained when taking as the contrast value the ratio between the target luminance and the average of the base light intensities at locations to the left and right of the target. Moreover, there is no difference between experimental and theoretical results. Conclusions are drawn as to the significance and drawbacks of target visibility levels for the assessment of road lighting. (Author/publisher)

Request publication

15 + 1 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
C 17983 [electronic version only] /85 / IRRD 865059
Source

International Journal of Lighting Research and Technology, Vol. 26 (1994), No. 1, p. 19-22, 4 ref.

Our collection

This publication is one of our other publications, and part of our extensive collection of road safety literature, that also includes the SWOV publications.