A collision of 36 fresh human femora was tested dynamically in torsion. All specimens failed with a spiral fracture surface. The results of a detailed stress analysis on one femur compared favorably with measured stiffness and published ultimate shear stress values.

Request publication

1 + 4 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

Publication

Library number
B 12586 (In: B 12556) /84/ IRRD 230701
Source

In: Proceedings of the 4th International Conference on Impact Trauma (IRCOBI), Berlin, September 7-9, 1977, p. 379-388, 2 fig., 3 graph., 2 tab., 5 ref.