Biofidelity of the Hybrid III thorax in high- velocity frontal impact

Auteur(s)
Horsch, J.D. & Schneider, D.
Jaar
Samenvatting

Blunt frontal thoracic impact of a Hybrid III dummy and three unembalmed human cadavers were conducted at the university of California, San Diego using a 4.25 Kg inertial impacter at a 13.4 M /s impact velocity. The dummy indicated a stiffer response than the cadaver subjects. The difference in average impact force was the same as the muscle tensing force added to the the human cadaver responses in developing recommended dummy response guidelines. These results further demonstrate the human- like response of the Hybrid III thorax over a wide range of frontal impact velocities.

Publicatie aanvragen

4 + 5 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
B 27411 (In: B 27401) /84 /
Uitgave

In: Automatic occupant protection systems. SAE publicatie Nr. SP- 736. Proceedings of the International Congress and Exposition, Detroit, Michigan, February 29 - March 4, 1988, p.115- 122, 12 ref. SAE Paper Nr.880718.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.