Development of a reusable, rate-sensitive abdomen for the Hybrid III family of dummies.

Auteur(s)
Rouhana, S.W. Elhagediab, A.M. Walbridge, A. Hardy, W.N. & Schneider, L.W.
Jaar
Samenvatting

The objective of this work was to develop a reusable, rate-sensitive dummy abdomen with abdominal injury assessment capability. The primary goal for the abdomen developed was to have good biofidelity in a variety of loading situations that might be encountered in an automotive collision. This paper presents a review of previous designs for crash dummy abdomens, a description of the development of the new abdomen, results of testing with the new abdomen and instrumentation, and suggestions for future work. The biomechanical response targets for the new abdomen were determined from tests of the mid abdomen done in a companion biomechanical study. The response of the abdominal insert is an aggregate response of the dummy's entire abdominal area and does not address differences in upper versus lower abdominal response, solid versus hollow organs, or organ position or mobility. While the abdomen developed has demonstrated good biofidelity in rigid bar, seat belt and airbag loading situations, some work remains to be done before it can be used in crash testing. (Author/publisher) For the covering abstract of the conference see ITRD E206605.

Publicatie aanvragen

4 + 16 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 23359 (In: C 23357 [electronic version only]) /84 / ITRD E206607
Uitgave

In: Stapp Car Crash Journal Volume 45 : papers presented at the 45th Stapp Car Crash Conference, San Antonio, Texas, USA, November 15-17, 2001, Technical Paper 2001-22-0002, p. 33-59, 62 ref.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.