Dynamic bending tolerance of the human forearm.

Auteur(s)
Pintar, F.A. & Yoganandan, N.
Jaar
Samenvatting

With the widespread use of supplemental restraint systems (airbags), occasional new injuries have developed because of the significant force associated with these systems upon deployment. Recent case studies have demonstrated forearm fractures associated with the deployment of the airbag. The present study was conducted to determine the tolerance of the human forearm under a dynamic bending mode. A total of 30 human cadaver forearm specimens were tested using three-point bending techniques to failure at 3.3 m/s and 7.6 m/s velocities. Results indicated significantly (p less than 0.01) greater biomechanical parameters associated with males compared to females. The bending tolerance of the human forearm was found to be most highly correlated to bone mineral density and forearm weight. The mean failure bending moment for all specimens was 94 Nm plus or minus 41, but for smaller-sized occupants with lower bone mineral it was approximately 45 Nm. The present investigation offers quantitative information regarding tolerance of the human forearm useful for design of injury-mitigating devices. (Author/publisher).

Publicatie aanvragen

16 + 1 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
I E115499 /84 / ITRD E115499
Uitgave

Traffic Injury Prevention. 2002 /03. 3(1) Pp43-8 (14 Refs.)

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.