Evaluation of the Biofidelity of the WorldSID and the ES-2 on the Basis of PMHS Data.

Auteur(s)
Damm, R. Schnottale, B. & Lorenz, B.
Jaar
Samenvatting

Under the European Side Impact Dummy Biomechanics and Experimental Research (SIBER) project, a 50th percentile WorldSID pre-production dummy was evaluated in several configurations. Heidelberg type sled tests and accidentreconstruction tests were conducted to verify the biofidelity, durabilityand repeatability. The sled test configurations consist of padded flat wall and padded pelvis offset. Under the same sled test conditions, BASt tested the ES-2 dummy as well for comparison. For the biofidelity rating, theresults were analysed and compared with PMHS data using the cumulative variance. In addition, two accident reconstructions were conducted to analyse the WorldSID performance for different accident severities. For the covering abstract see ITRD E141569.

Publicatie aanvragen

10 + 0 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 46184 (In: C 46159 CD-ROM) /84 /91 / ITRD E141586
Uitgave

In: Proceedings of the 2006 International IRCOBI Conference on the Biomechanics of Impact, Madrid (Spain), September 20-22, 2006, Pp.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.