An evaluation of prototype seats using BioRID-P3 and Hybrid III with TRID neck.

Auteur(s)
Ishikawa, T. Okano, N. Ishikura, K. & Ono, K.
Jaar
Samenvatting

There has been some discussion on whether Hybrid III can accurately evaluate the risk of low-severity neck injuries in rear impacts because it has been developed for the evaluation of frontal impacts. A new dummy with an articulated spine and a flexible torso has been developed. The newest prototype, BioRID P3 has been compared with volunteer data at delta V (velocity change) 9 km/h and it was found to respond with a good biodidelity. The object of this study is to clarify the difference of response between the BioRID and the Hybrid III from tests using prototype seats at delta V 15 km/h. The characteristics of human kinematics which were confirmed in lower speed BioRID tests were also confirmed at delta V 15 km/h. The upper neck shear forces and moments and Neck Injury Criterion (NIC) of the BioRID were significantly different from those of Hybrid III. (A)

Publicatie aanvragen

3 + 3 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 19095 (In: C 19067) /84 /91 / ITRD E206450
Uitgave

In: Proceedings of the 2000 International IRCOBI Conference on the Biomechanics of Impacts, Montpellier, France, September 20-22, 2000, p. 379-391, 27 ref.