Feasibility of transdermal ethanol sensing for the detection of intoxicated drivers.

Auteur(s)
Webster, G.D. & Gabler, H.C.
Jaar
Samenvatting

Transdermal ethanol detection is a promising method that could prevent drunk driving if integrated into an ignition interlock system. However, experimental data from previous research has shown significant time delays between alcohol ingestion and detection at the skin which makes real time estimation of blood alcohol concentration via skin measurement difficult. Using a validated model we studied the effects that body weight, metabolic rate and ethanol dose had on the time lag between the blood alcohol concentration and transdermal alcohol concentration. The dose of alcohol ingested was found to have the most significant effect on the skin alcohol lag time; a dose of 15 ml of ethanol resulted in a peak lag time of approximately 33 minutes, while a dose of 60 ml of ethanol resulted in a peak time lag of 53 minutes. The time lag was found to be insensitive to body mass and only moderately sensitive to changes in metabolic rates. (Author/publisher)

Publicatie aanvragen

12 + 0 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
20072253 a27 ST (In: ST 20072253 CD-ROM)
Uitgave

In: Proceedings of the 51st Annual Conference of the Association for the Advancement of Automotive Medicine AAAM, Melbourne, Australia, October 14-17, 2007, p. 449-464, 12 ref.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.