High early strength latex-modified concrete overlay.

Auteur(s)
Sprinkle, M.M.
Jaar
Samenvatting

This paper describes the condition of the first high early strength latex-modified concrete (LMC-HE) overlay to be constructed for the virginia department of transportation. The overlay was prepared with type III cement and with more cement and less water than is used in the conventional latex-modified concrete (LMC) overlay. Tests of the bond and compressive strength of the LMC-HE overlay performed during the first 24 hr after installation indicated that traffic could be placed on the overlay within 24 hr rather than the 4-7 days required for the conventional LMC overlay. Tests of the bond strength and permeability to chloride ion conducted after 1 yr in service indicate that the overlay is performing satisfactorily. Pending continuing favourable test results, it is anticipated that LMC-HE overlays can be used in situations in which it is desirable to accelerate construction, to reduce inconvenience to motorists, to allow for installation during off-peak traffic periods such as weekends, to provide a more rapid cure in cold weather, to provide low permeability (compared to concrete without latex), and to provide high strength, particularly, high early strength.

Publicatie aanvragen

9 + 4 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 18921 (In: C 18914 S) /32 / IRRD 828156
Uitgave

In: Portland cement concrete modifiers, Transportation Research Record TRR 1204, p. 42-51, 14 ref.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.