High speed impact test on a 40ft lighting column fitted with a break-away joint.

Auteur(s)
Hignett, H.J.
Jaar
Samenvatting

As part of the programme to develop safer street lighting columns for use on high speed roads a test has been carried out on a tubular steel column 40 ft high fitted with a shear joint at ground level. To simulate the case when a car runs off the carriageway on a high speed road, a medium sized saloon car was remotely steered into the column at a speed of approximately 60 mile/h. The main findings are: (1) the deceleration of the colliding car was so slight (an average of 2.2 for 0.05 seconds) that it is unlikely that occupants would have been seriously injured, (2) the bottom of the column shaft was pushed away so that the car passed under it, and (3) the column fell behind the car. It is concluded that the incorporation of a shear joint of the type tested into tall tubular or other steel lighting columns of normal height would greatly reduce the severity of injuries to the occupants of high speed motor vehicles colliding with the columns.