Samenvatting
The head, test and femurs of three Hybrid II dummies were impacted to determine what differences in accelerometer and femur load cell output would result for a constant energy output. It was found that the dummy legs can be subjected to very high torsion and bending loads which can have a significant effect on the femur load cell axial load outputs.