Innovative structural backfills to integral bridge abutments. Prepared for Highways Agency, Quality Services, Civil Engineering.

Auteur(s)
Carder, D.R. & Card, G.B.
Jaar
Samenvatting

Investigations have confirmed that most bridge deck expansion joints leak and contribute more than any other factor to deck and substructure corrosion from de-icing salts. For this reason joint-free integral bridges, with the abutments structurally connected to a continuous deck, are more durable and cheaper to maintain. However, thermal strains in an integral deck cause cyclic loading on the soil behind the abutments, which may result in the development of passive soil pressures. One method of avoiding the development of high lateral pressures is to use a low stiffness but compressible elastic backfill as a stress absorbing layer behind the abutment. This report identifies various compressible materials, for example polymeric and geocomposite materials, which may be suitable for use as innovative structural backfill behind integral bridge abutments. (A)

Publicatie

Bibliotheeknummer
C 9718 [electronic version only] /24 /42 / IRRD 894634
Uitgave

Crowthorne, Berkshire, Transport Research Laboratory TRL, 1997, III + 26 p., 60 ref.; TRL Report ; No. 290 - ISSN 0968-4107

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.