Measurement of detailed inertial proporties and dimensions of 50th percentile anthropometric dummy.

Auteur(s)
Naab, K.N.
Jaar
Samenvatting

The dimensions and inertial properties of the segments of an Alderson, 50th percentile anthropometric dummy were measured. The dummy, model F-50-AU, was disassembled into 10 main segments and measurements of weights. Lengths, center of gravity positions, and moments of inertia were performed on each segments. Lengths were measured directly with a scale and weighs were determined on a scale balance. A "balance tests" was performed on each segment to determine its center of gravity position. Moment of inertia data were measured by means of a torsional pendulum apparatus. A comparison is presented of these data with measured data of a Swedish dummy, type DV, and available human cadaver data.

Publicatie aanvragen

9 + 3 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
A 3559 (In: A 381 S [electronic version only])
Uitgave

In: Proceedings of Tenth Stapp Car Crash Conference, November 8-9, 1966, SAE paper 660795, 9 p.