Monitoring of particulate matter less than 2.5 microns along the Borman Expressway.

Auteur(s)
Schneider, W.H. Labreche, T.M.C. Bullock, D. & Jacko, R.B.
Jaar
Samenvatting

The purpose of this study was to monitor normal daily traffic and to correlate traffic congestion with ambient levels of particulate matter less than 2.5 microns (PM2.5) from the Borman Expressway in Hammond, IN. Traffic data collection with the assistance of the Indiana Department of Transportation began on June 7, 2001. The 3M Intelligent Transportation Systems Canoga C800IS software at milepost 3.5 along the Borman Expressway collected vehicle volumes and occupancies. The tapered element oscillating microbalance (TEOM) located approximately 150 feet south of the Borman expressway near milepost 4.1, measured ambient PM2.5 every ten-seconds. Traffic congestion occurred on eastbound lane B between 10:00 AM and 1:00 PM on June 8, 2001, which resulted in an increase of 400% in PM2.5 flux.

Publicatie aanvragen

1 + 0 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 31568 (In: C 31321 CD-ROM) /15 / ITRD E826329
Uitgave

In: ITS - enriching our lives : proceedings of the 9th World Congress on Intelligent Transportation Systems ITS, Chicago, Illinois, October 14-17, 2002, 11 p.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.