Ocular injuries due to projectile impacts.

Auteur(s)
Scott, W.R. Lloyd, W.C. Benedict, J.V. & Meredith, R.
Jaar
Samenvatting

An animal model has been developed using enucleated porcine eyes to evaluate ocular trauma. The eyes were pressurized to approximately 18 mm Hg and mounted in a container with a 10% gelatin mixture. The corneas of sixteen pressurized eyes were impacted by a blunt metal projectile (mass of 2.6 gm, 3.5 gm or 45.5 gm) at velocities of 4.0 to 38.1 m/s. The impacted eyes were evaluated by an ophthalmologist. A numerical classification scheme was used to categorise the severity of the ocular injury. A chi-squared test indicates that the injury level is associated with the kinetic energy (KE) and not the momentum of the projectile. The enucleated eyes began to experience lens dislocations when the KE of the projectile was approximately 0.75 Nm, and retinal injuries when the KE was approximately (A)

Publicatie aanvragen

4 + 1 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 18005 (In: C 17992 S) /84 / ITRD E203797
Uitgave

In: Proceedings of the 44th Annual Conference of the Association for the Advancement of Automotive Medicine AAAM, Chicago, Illinois, October 2-4, 2000, p. 205-217, 8 ref.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.