Performance of piles supporting integral bridges.

Auteur(s)
Arsoy, S. Duncan, J.M. & Barker, R.M.
Jaar
Samenvatting

Cyclic lateral load tests simulating 75 years of bridge life were performed on an H-pile, a pipe pile, and a prestressed reinforced concrete pile by applying over 27,000 displacement cycles. The data from the tests indicate that steel H-piles loaded on the weak axis are the best pile type for support of integral abutment bridges. Concrete piles are not recommended for integral bridge support because, under repeated lateral loads, tension cracks progressively worsen and significantly reduce vertical load carrying capacity of these piles. Steel pipe piles are stiffer than H-piles loaded on the weak axis, and therefore induce higher stresses in the abutment where they are embedded.

Publicatie aanvragen

2 + 0 =
Los deze eenvoudige rekenoefening op en voer het resultaat in. Bijvoorbeeld: voor 1+3, voer 4 in.

Publicatie

Bibliotheeknummer
C 29830 (In: C 29811 S [electronic version only]) /42 /53 / ITRD E822712
Uitgave

In: Soil mechanics 2002, Transportation Research Record TRR 1808, p. 162-167, 5 ref.

Onze collectie

Deze publicatie behoort tot de overige publicaties die we naast de SWOV-publicaties in onze collectie hebben.